UB series power supply adopts online double conversion design and digital control technology and it features high input and output power factor(0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effetive power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
General Features
● True double-conversion
● Digital control guarantees high reliability
● ECO mode operation for energy saving
● Output receptacle control for non-critical load shedding capability
● Emergency power off function(EPO)
● Generator compatible
● Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional)
● Bypass can be used when UPS is off(Setted in LCD)
● Cold start
Technical Specification
MODEL
UB
10-24
UB
10
UB
10L
UB
15
UB
15L
UB
20-48
UB
20
UB
20-96
UB
20L
UB
20L-96
UB
30
UB
30-96
UB
30L
UB
30L-96
Capacity
(VA/Watts)
1000VA/900W
1500VA/1350W
2000VA/1800W
3000VA/2700W
INPUT
Nominal
Voltage
208/ 220/230/240Vac(L+N+PE)
Operating
Voltage
Range
110~300Vac @(0~60%) Load;120~300Vac @(60~70%)Load,140~300Vac @(70~80%)Load;
160~300Vac @(80~100%)Load
Operating
Frequency
Range
50Hz:45~55Hz,60Hz: 55-65Hz Auto Sensing
Power Factor
> 0.85@25%Load;>0.95 @50%Load;>0.97@75%Load;>0.99 @ Nominal voltage& 100%Load
OUTPUT
Output Voltage
208/220/230/240Vac:230Vac(Default)
Power Factor
0.9
Voltage
Regulation
±1%
Frequency
Synchronized
Range
45-55Hz ±0.02Hz@ 50Hz, 55-65Hz ±0.02Hz@60Hz
Battery Mode
&None
Synchronized Range
(50/60±0.02)Hz
Crest Factor
3:1
Harmonic
Distortion
(THDv)
≤3% with linear load
≤5% with non-linear load
Waveform
Pure Sinewave
Transfer Time
Utility to Battery : 0ms; Utility to Bypass: 4ms(Typical)
EFFICIENCY
AC Mode
88%
88%
89%
90%
Battery Mode
84%
85%
85%
85%
86%
87%
ECO Mode
>93%
>94%
BATTERY
Battery Type
12V/9AH
12V
12V/9AH
12V
12V/9AH
12V/7AH
12V
12V/9AH
12V/7AH
12V
Numbers
2
3
3*N
3
3*N
4
6
8
6*N
8*N
6
8
6*N
8*N
Maximum
Charging
Current (A)
1.0
6.0/12.0
1.0
6.0/12.0
1.0
6.0/12.0
1.0
6.0/12.0
Charging
Voltage(Vdc)
27.4V±1%
41.1V±1%
41.1V
±1%
54.8±1%
82.2V±1%
109.6V±1%
82.2V±1%
109.6V±1%
82.2V±1%
109.6V±1%
82.2V±1%
109.6V±1%
Protect
Over-voltage(14.7v) /Low-voltage(10v)
PROTECTION
Overlo ad
Capacity
Line Mode
105%-150%, 30s turn to bypass mode ; >150% 300ms turn to bypass mode
Battery Mode
105%-150%, exceed 30s shutdown ; >150% exceed 300ms shutdown
INDICATORS
LED & LCD Display
Load/Battery/Input/Output/Operating Mode Information
ALARM
Battery Mode
Sounding every 4 seconds
Battery Low
Sounding every second
Overload
Sounding every 0.5 second
Fault
Continuously Sounding
MANAGEMENT
Smart RS-232/USB
(Preferential)
External Modbus card supported by RS232,Software supports Windows Family,Linus,FreeBSD
Intelligent Slot
SNMP (Standard or mini) independent to RS-232(Optional)
ENVIRONMENT
Operating
Temperature
0℃~40℃
Humidity Range
0~95% (Non-condensing)
Altitude
< 1500m
Noise Level
<50dB@ 1Meter
PHYSICAL
Dimension
W×D×H (mm)
144×400×215
191×468×337
Net Weight (kg)
11.3
13.7
5.9
13.9
6.2
21.9
26.9
29.6
10.6
10.8
27.4
30.1
11.1
11.3
STANDARDS
Safety
IEC/EN62040-1
EMC
IEC/EN62040-2