The MatrixAir™ precision cooling system has been developed to meet the increasing demand for ultra-efficient and large capacity. It is a room-based cooling system that can deliver efficient, precise, reliable control of room temperature, humidity and airflow for the proper operation of critical electronic equipment. A wide range of standard units offered from 25 KW to 300 KW in upflow & downflow configurations. Patent fan design can save up to 30% energy when compared with competitor units, helping data center facilities deliver best-in-class PUEs. Optional cooling source boosts cooling system availability and reliability!
The MatrixAir™ precision cooling system has been developed to meet the increasing demand for ultra-efficient and large capacity. It is a room-based cooling system that can deliver efficient, precise, reliable control of room temperature, humidity and airflow for the proper operation of critical electronic equipment. A wide range of standard units offered from 25 KW to 300 KW in upflow & downflow configurations.
Patent fan design can save up to 30% energy when compared with competitor units, helping data center facilities deliver best-in-class PUEs. Optional cooling source boosts cooling system availability and reliability!
General Features
● Total cooling capacity: 25kW~300kW
● Power-saving and environment-friendly technology
● First class components make MatrixAir more stable
● 7 kinds of cooling types
● Many components can be replaced with different type according customer’s requirement
● Modular structure design eases the transportation 、installation and services
● Patent fan design can reduce 30% energy. The fan supports sinking deployment and non-sinking deployment
● R407 refrigerant, and also compatible with R22 refrigerant (low cost)
● Fluorine pump can save more than 50% energy by using nature cold source
Technical Specification
Air MT***UD
Unit
25
30
35
45
55
40
50
60
70
80
90
100
Water MT***
AC Fan
Air volume
m³/h
7500
8000
8500
13000
15000
12500
14000
18000
18500
21000
23000
25000
DX Total Cooling
Capacity
kW
26.7
30.8
35.5
45.5
54.5
41.2
53.5
61.4
70.9
81.3
90.6
104.4
DX Sensible Cooling
Capacity
kW
24.3
29.3
32.7
42.8
51.8
37.9
49.2
57.7
63.8
77.2
83.4
95
DX Sensible heat raio
/
0.91
0.95
0.92
0.94
0.95
0.92
0.92
0.94
0.9
0.95
0.92
0.91
CW Total Cooling
Capacity
kW
27.6
32.4
41.2
56.5
61.5
54.5
59.3
67.4
71
90.6
97.6
106.6
CW Sensible Cooling
Capacity
kW
25.3
29.3
36.6
50.2
55.6
47.8
53.5
60.5
64.1
80.8
87.9
94.8
CW Sensible heat raio
/
0.92
0.9
0.89
0.89
0.9
0.88
0.9
0.9
0.9
0.89
0.9
0.89
Water flow capacity
m3/h
4.75
5.58
7.13
9.75
10.53
9.33
10.14
11.55
11.99
14.03
16.8
18.21
Pressure drop
Kpa
51.6
75.3
93.3
85.5
99
77.6
92.2
62.2
68
97.4
104.8
124.1
EC Fan
Air volume
m³/h
7800
8300
8800
13500
15400
13200
14600
18700
19300
21600
23900
26000
DX Total Cooling
Capacity
kW
26.9
31.2
35.7
45.9
54.7
41.6
53.8
61.7
71.1
81.8
90.8
104.7
DX Sensible Cooling
Capacity
kW
25
30
33.6
44.1
52.5
39.5
50.6
59.2
66.1
78.5
85.4
97.4
DX Sensible heat raio
/
0.93
0.96
0.94
0.96
0.96
0.95
0.94
0.96
0.93
0.96
0.94
0.93
CW Total Cooling
Capacity
kW
28.3
33.2
42.8
57.3
62.3
55.3
60.2
67.9
71.7
91.3
98.1
108.2
CW Sensible Cooling
Capacity
kW
26.4
29.8
38.5
51.6
56.5
49.7
54.7
61.2
64.5
83.1
90
97.6
CW Sensible heat raio
/
0.93
0.9
0.9
0.9
0.91
0.9
0.91
0.9
0.9
0.9
0.9
0.9
Water flow capacity
m³/h
4.9
5.7
7.3
10
10.7
9.6
10.4
11.8
12.3
14.3
17.2
18.6
Pressure drop
Kpa
54
78
95
89
102
82
96
65
71
100
109
126
Heating capacity
(standard)
kW
6
6
6
9
9
9
9
9
9
12
12
12
Heating capacity
(Max)
kW
12
12
12
18
18
18
18
18
18
24
24
24
Humidifying capacity
(Standard)
Kg/h
6
8
8
10
10
10
10
10
10
12
12
12
Humidifying capacity
(Max)
Kg/h
8
8
8
15
15
15
15
15
15
15
15
15
Number of compressors
Pcs
1
1
1
1
1
2
2
2
2
2
2
2
Number of fan
Pcs
1
1
1
2
2
2
2
2
2
3
3
3
Full-load Current
(Air cooled and
chilled water)
A
28.8
32.7
35.1
48.3
54.4
48.3
53.6
58.7
63.5
76.3
81.7
96.6
Full-load Current
(Water cooled and
chilled water)
A
26.1
27.3
29.7
42.9
49
38.4
48.2
50.6
55.4
68.2
73.6
85.8
Size of inlet and
outlet water pipes
mm
28
28
35
35
35
35
35
35
35
42
42
42
Unit Weight
kg
400
470
480
640
650
700
730
800
810
1020
1040
1140
Unit Width
mm
850
1200
1200
1650
1650
1650
1650
2010
2010
2460
2460
2810
Unit Depth
mm
850
850
850
850
850
850
850
850
850
850
850
850
Unit Height
mm
1960
1960
1960
1960
1960
1960
1960
1960
1960
1960
1960
1960
Note :
● Parameter table
Air/water cooled unit data based on 24°C,50%RH indoor return air temperature.
Chilled water unit data based on 24°C,50%RH indoor return air temperature。The inlet and outlet water temperature of chilled water are 7°C and 12°C。
Electirc heating adopts three-level hierarchical control
●The power supply type:380`415V/3p/50Hz
●We can provide other customized product.If you need more information,please contact us.
●Specifications are subject to change without prior notice