MatrixAir TM Series

    Reviews (67)

  • Sold: 153

Add to Quote

  • Brand

    Kstar

Quantity

About Product

The MatrixAir™ precision cooling system has been developed to meet the increasing demand for ultra-efficient and large capacity. It is a room-based cooling system that can deliver efficient, precise, reliable control of room temperature, humidity and airflow for the proper operation of critical electronic equipment. A wide range of standard units offered from 25 KW to 300 KW in upflow & downflow configurations. Patent fan design can save up to 30% energy when compared with competitor units, helping data center facilities deliver best-in-class PUEs. Optional cooling source boosts cooling system availability and reliability!

The MatrixAir™ precision cooling system has been developed to meet the increasing demand for ultra-efficient and large capacity. It is a room-based cooling system that can deliver efficient, precise, reliable control of room temperature, humidity and airflow for the proper operation of critical electronic equipment. A wide range of standard units offered from 25 KW to 300 KW in upflow & downflow configurations.

Patent fan design can save up to 30% energy when compared with competitor units, helping data center facilities deliver best-in-class PUEs. Optional cooling source boosts cooling system availability and reliability!

General Features

● Total cooling capacity: 25kW~300kW

● Power-saving and environment-friendly technology

● First class components make MatrixAir more stable

● 7 kinds of cooling types

● Many components can be replaced with different type according customer’s requirement

● Modular structure design eases the transportation 、installation and services

● Patent fan design can reduce 30% energy. The fan supports sinking deployment and non-sinking deployment

● R407 refrigerant, and also compatible with R22 refrigerant (low cost)

● Fluorine pump can save more than 50% energy by using nature cold source

Technical Specification

Air MT***UD

Unit

25

30

35

45

55

40

50

60

70

80

90

100

Water MT***

AC Fan

Air volume

m³/h

7500

8000

8500

13000

15000

12500

14000

18000

18500

21000

23000

25000

DX Total Cooling

Capacity

kW

26.7

30.8

35.5

45.5

54.5

41.2

53.5

61.4

70.9

81.3

90.6

104.4

DX Sensible Cooling

Capacity

kW

24.3

29.3

32.7

42.8

51.8

37.9

49.2

57.7

63.8

77.2

83.4

95

DX Sensible heat raio

/

0.91

0.95

0.92

0.94

0.95

0.92

0.92

0.94

0.9

0.95

0.92

0.91

CW  Total Cooling

Capacity

kW

27.6

32.4

41.2

56.5

61.5

54.5

59.3

67.4

71

90.6

97.6

106.6

CW Sensible Cooling

Capacity

kW

25.3

29.3

36.6

50.2

55.6

47.8

53.5

60.5

64.1

80.8

87.9

94.8

CW Sensible heat raio

/

0.92

0.9

0.89

0.89

0.9

0.88

0.9

0.9

0.9

0.89

0.9

0.89

Water flow capacity

m3/h

4.75

5.58

7.13

9.75

10.53

9.33

10.14

11.55

11.99

14.03

16.8

18.21

Pressure drop

Kpa

51.6

75.3

93.3

85.5

99

77.6

92.2

62.2

68

97.4

104.8

124.1

EC Fan

Air volume

m³/h

7800

8300

8800

13500

15400

13200

14600

18700

19300

21600

23900

26000

DX Total Cooling

Capacity

kW

26.9

31.2

35.7

45.9

54.7

41.6

53.8

61.7

71.1

81.8

90.8

104.7

DX Sensible Cooling

Capacity

kW

25

30

33.6

44.1

52.5

39.5

50.6

59.2

66.1

78.5

85.4

97.4

DX Sensible heat raio

/

0.93

0.96

0.94

0.96

0.96

0.95

0.94

0.96

0.93

0.96

0.94

0.93

CW  Total Cooling

Capacity

kW

28.3

33.2

42.8

57.3

62.3

55.3

60.2

67.9

71.7

91.3

98.1

108.2

CW Sensible Cooling

Capacity

kW

26.4

29.8

38.5

51.6

56.5

49.7

54.7

61.2

64.5

83.1

90

97.6

CW Sensible heat raio

/

0.93

0.9

0.9

0.9

0.91

0.9

0.91

0.9

0.9

0.9

0.9

0.9

Water flow capacity

m³/h

4.9

5.7

7.3

10

10.7

9.6

10.4

11.8

12.3

14.3

17.2

18.6

Pressure drop

Kpa

54

78

95

89

102

82

96

65

71

100

109

126

Heating capacity

(standard)

kW

6

6

6

9

9

9

9

9

9

12

12

12

Heating capacity

(Max)

kW

12

12

12

18

18

18

18

18

18

24

24

24

Humidifying capacity

(Standard)

Kg/h

6

8

8

10

10

10

10

10

10

12

12

12

Humidifying capacity

(Max)

Kg/h

8

8

8

15

15

15

15

15

15

15

15

15

Number of compressors

Pcs

1

1

1

1

1

2

2

2

2

2

2

2

Number of fan

Pcs

1

1

1

2

2

2

2

2

2

3

3

3

Full-load Current

(Air cooled and

chilled water)

A

28.8

32.7

35.1

48.3

54.4

48.3

53.6

58.7

63.5

76.3

81.7

96.6

Full-load  Current

(Water cooled and

chilled water)

A

26.1

27.3

29.7

42.9

49

38.4

48.2

50.6

55.4

68.2

73.6

85.8

Size of inlet and

outlet water pipes

mm

28

28

35

35

35

35

35

35

35

42

42

42

Unit Weight

kg

400

470

480

640

650

700

730

800

810

1020

1040

1140

Unit Width

mm

850

1200

1200

1650

1650

1650

1650

2010

2010

2460

2460

2810

Unit Depth

mm

850

850

850

850

850

850

850

850

850

850

850

850

Unit Height

mm

1960

1960

1960

1960

1960

1960

1960

1960

1960

1960

1960

1960

Note :

● Parameter table

Air/water cooled unit data based on 24°C,50%RH indoor return air temperature.

Chilled water unit data based on 24°C,50%RH indoor return air temperature。The inlet and outlet water temperature of chilled water are 7°C and 12°C。

Electirc heating adopts three-level hierarchical control

●The power supply type:380`415V/3p/50Hz

●We can provide other customized product.If you need more information,please contact us.

●Specifications are subject to change without prior notice

Brands we stock
cisco.svg
asus.png
fortinet.png
dell.png
idXrlLpGCL_logos.png
HPE_Main_Logo.png
hikvision.png
cisco.svg
asus.png
fortinet.png
dell.png
idXrlLpGCL_logos.png
HPE_Main_Logo.png
hikvision.png
cisco.svg
asus.png
fortinet.png
dell.png
idXrlLpGCL_logos.png
HPE_Main_Logo.png
hikvision.png
Compare
Products
Your compare is curently empty
Compare Products
MatrixAir TM Series | Buy in Dubai, UAE | Codeeotech