واحة دبي للسيليكون, Dubai
Brand
KstarQuantity
With a 7-inch colour touch screen, hot-swappable design, HPM3300E modular UPS features high efficiency (95.8%), high power density, easy scaling, scaling on demand, Parallel redundancy function and occupies only a small amount of floor area and provides safe, reliable, and clear environmentally friendly power to loads. The series' N+X module and built-in system redundancy maintain a steady, reliable source of energy. It can provide the highest level of power protection and has been widely used in various industries such as IT rooms, data centers, banking, healthcare, insurance, and telecommunications.
With a 7-inch colour touch screen, hot-swappable design, HPM3300E modular UPS features high efficiency (95.8%), high power density, easy scaling, scaling on demand, Parallel redundancy function and occupies only a small amount of floor area and provides safe, reliable, and clear environmentally friendly power to loads.
The series’ N+X module and built-in system redundancy maintain a steady, reliable source of energy. It can provide the highest level of power protection and has been widely used in various industries such as IT rooms, data centers, banking, healthcare, insurance, and telecommunications.
General Features
● Modular design, including power module, bypass module, monitoring module, which means it can be easily integrated in MDC or customized cabinet.
● Flexible power module: 10/15/20/25/30kVA ((2U))
● High input power factor, it is up to 0.99.
● Width input voltage range:line voltage range is 138-485V, UPS would be derating when input voltage is below 305V.
● Parallel redundant configurations:failure of one module will not impact system or site operation.
● Three level topology design, efficiency is up to 95.8%.
● Sleeping Mode to save energy.
● Support parallel expanded operation: maximum is 6 units, Support sharing batteries for the UPS in parallel.
General Features
Module Model
HPM3300E-RM-10
Cabinet Model
HPM3300E-20
HPM3300E-40
HPM3300E-60
Cabinet capacity (VA)
10k~20k
10k~40k
10k~60k
Module capacity (VA)
10k
Max. Number
2
4
6
Module Model
HPM3300E-RM-15
Cabinet Model
HPM3300E-30
HPM3300E-60
HPM3300E-90
Cabinet capacity (VA)
15k~30k
15k~60k
15k~90k
Module capacity (VA)
15k
Max. Number
2
4
6
Module Model
HPM3300E-RM-20
Cabinet Model
HPM3300E-40
HPM3300E-80
HPM3300E-120
Cabinet capacity (VA)
20k~40k
20k~80k
20k~120k
Module capacity (VA)
20k
Max. Number
2
4
6
Module Model
HPM3300E-RM-25
Cabinet Model
HPM3300E-50
HPM3300E-100
HPM3300E-150
Cabinet capacity (VA)
25k~50k
25k~100k
25k~150k
Module capacity (VA)
25k
Max. Number
2
4
6
Module Model
HPM3300E-RM-30
Cabinet Model
HPM3300E-60
HPM3300E-120
HPM3300E-150
Cabinet capacity (VA)
30k~60k
30k~120k
30k~150k
Module capacity (VA)
30k
Max. Number
2
4
5+1
INPUT
Nominal voltage
380/400/415Vac, (3Ph+N+PE)
Operating voltage range
138~305Vac for 40% Load; 305~485Vac for 100% Load;
Operating frequency range
40Hz-70Hz
Power factor
≥0.99
Harmonic distortion (THDi)
≤3% (100% linear load)
Bypass voltage range
Max. voltage:220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%)
Min. voltage: -45% (optional-10%, -15%, -20%, -30%)
Bypass frequency range
Frequency protection range: ±10%
Power Walk In
Support
Generator input
Support
OUTPUT
Rated voltage
380/400/415Vac, (3Ph+N+PE)
Power factor
1.0
Voltage regulation
±1%
Output frequency
Line Mode
Synchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz)
Bat. Mode
(50/60±0.1%)Hz
Crest factor
3:1
Harmonic distortion (THDv)
≤1% with linear load; ≤3% with nonlinear load
Efficiency
up to 95.8%
BATTERY
Battery voltage
Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional);
360Vdc~600Vdc (30~50 pcs, 36 pcs default, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8)
Power module charge current
18A (Max.)
SYSTEM FEATURES
Transfer time
Utility to Battery : 0ms; Utility to bypass: 0ms
Overload
Line Mode
≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately.
Bypass Mode
135% overload for long term; >1000% overload for 100 ms
Overheat
Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Low battery voltage
Alarm and Switch off
Self-diagnostics
Upon Power On and Software Control
Backfeed
Support
EPO
Shut down UPS immediately (turn to bypass optional)
Battery
Advanced Battery Management
Noise suppression
Complies with EN62040-3
Audible & Visual alarms
Line Failure, Battery Low, Overload, System Fault
Status LED & LCD display
Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault
Reading on the LCD display
Input, Output, Battery, Command, Setting, Maintenance
Communication interface
RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional)
ENVIRONMENTAL
Operating temperature
0℃~40℃
Storage temperature
-25℃~55℃
Humidity range
0~95% (non condensing)
Altitude
<1500m, derating required when >1500m
Noise level(from 1M distance)
<58dB
<60dB
<62dB
PHYSICAL
Dimension W×D×H (mm)
UPS cabinet
485×850×353(8U)
485×850×575(13U)
485×850×752(17U)
Power module
440×620×86(2U)
Net weight (kg)
UPS cabinet
69
79
98
Power module
10kVA: 19; 15~30kVA: 21
STANDARDS
Safety
IEC/EN62040-1, IEC/EN62477-1
EMC
IEC/EN62040-2 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8)
Specifications are subject to change without prior notice.