UCR60-100 series UPS is a Rack/Tower convertible UPS solutions which integrates true double-conversion design, DSP technology to provide clean high-level quality power as well as better voltage conditions to different application. What's more, with N+X parallel redundancy, it can achieve higher availability and MTBF (mean time between failure) to fully protect mission-critical devices.
UCR60-100 series UPS is a Rack/Tower convertible UPS solutions which integrates true double-conversion design, DSP technology to provide clean high-level quality power as well as better voltage conditions to different application. What’s more, with N+X parallel redundancy, it can achieve higher availability and MTBF (mean time between failure) to fully protect mission-critical devices.
General Features
● True double-conversion
● Rack-mounted and floor-standing tower can be convertible
● LCD panel can be rotated according to the type of deployment
● DSP technology guarantees high reliability
● N+X parallel redundancy
● Compatible with 3 phases and single phase input
● Selectable quantity of battery for each group:16/18/20 pieces
● Adjustable charging current via LCD
● 3-stage charging design optimizes battery performance
● ECO mode operation for energy saving
● Self-diagnosis at startup
● Emergency power off function(EPO)
● Maintenance bypass is convenient for maintenance
● Generator compatible
● Communications:RS-232,USB,Parallel card(Optional),SNMP card(Optional), Relay card (Optional)
● Cold start
Technical Specification
MODEL
UCR60L
UCR100L
Capacity (VA/Watts)
6K / 5.4K
10K / 9K
INPUT
Nominal Voltage
380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE)
Operating Voltage
Range
208~478Vac or 120VAC-276Vac
Operating Frequency
Range
50Hz:45~55Hz,60Hz:54~66Hz
Power Factor
≥0.99
Bypass Voltage
Range
Max.voltage: 220V:+25%(Optional +10%,+15%,+20% )
230V:+20%(Optional +10%,+15%)
240V:+15%(Optional +10% )
Min. voltage: -45% (Optional -20%,-30%)
ECO Range
Same as bypass
Harmonic
Distortion (THDi)
≤5%(100% non-linear load)
OUTPUT
Output Voltage
220/230/240Vac
Power Factor
0.9
Voltage Regulation
±1%
Frequency
Line Mode
±1%/±2%/±4%/±5%/±10% of the rated frequency(Optional)
Bat.Mode
(50/60±0.1)Hz
Crest Factor
3:1
Harmonic
Distortion (THD)
≤2% with linear load
≤5% with non-linear load
Waveform
Pure Sinewave
Transfer Time
Utility to Battery : 0ms; Utility to Bypass: 0ms
EFFICIENCY
Efficiency
Up to 94%
BATTERY
Battery Voltage
Selectable Voltage: ±96/108/120Vdc
Typical Recharge Time
6-8 hours (To 90% capacity)
Charging Current
Maximum current 10A
PROTECTION
Overload
Line Mode
Load≤125%: last 5min;≤150%: last 1min;>150% 200ms turn to bypass mode
Bypass Mode
40A(Input breaker)
63A(Input breaker)
Short Circuit
Hold Whole System
Overheat
Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
Battery Low
Alarm and Switch off
INDICATORS
Audible &Visual Alarms
Line Failure, Battery Low, Overload, System Fault
Status LED &LCD Display
Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Parameters On
The LCD Panel
Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level, Inner Temperature & Remaining Battery Backup Time
MANAGEMENT
Communication Interface
RS-232,USB,Parallel card, SNMP card(Optional), Relay card (Optional)
ENVIRONMENT
Operating Temperature
0℃~40℃
Storage Temperature
-25℃~55℃
Humidity Range
0~95% (Non-condensing)
Altitude
< 1500m
Noise Level
<55dB
PHYSICAL
Dimension W×H×D (mm)
443×131×580(3U)
Net Weight (kg)
30
31
STANDARDS
Noise Suppression
Complies with EN62040-2
Safety
IEC/EN62040-1,IEC/EN60950-1
EMC
IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8
BATTERY PACK
Model
EXBR±120V
Battery type&
Max.quantity
7Ah×20/9Ah×20
Dimensions
W×H×D (mm)
443×131×720(3U)
Net Weight (kg)
67